PENGUKURAN KAPASITAS SIMPAN RELATIF BERBAGAI TIPE SIMCARD MENGGUNAKAN CITRA RADIOGRAFI

SRI MAIYENA

Abstract


This research was aimed at finding out the usage of radiological physics, i.e. the use of radiology in projecting the image of a constituent material without damaging the outer profile, calibrating radiological picture with aluminum profiles and measuring the relative sim card storage capacity of hand phones. The test was conducted to five types of sim cards along with a ladder-shaped aluminum profile. Photography radiology was performed energy 50 kv. Then the analysis of image quality was done by using software of new image analyzer 2007.  Image calibration process was done by using the results of aluminum profile image. The results of the photographic image were recorded 20 times, and then selected the best image. Then the image result obtained was used to calibrate the thickness of aluminum profile. From the calibration it was found the function equationof the grayscale, y=143,9e-0,18x with the correlation 0,974. As the result of the calibration, it was obtained the relative thickness of sim cards toward aluminum; between 0,3877 – 0,7423mm. The density measurement of the sim card with grayscale was ranging between 125-134. The density shows the relative simcard storage capacity.

Key words: storage capacity, radiographic images, simcard

References


Buzug TM. 2008. Computed Tomography From Photon Statistics to Modern Cone-Beam CT, springer-Verlag Berlin Heidelberg: Germany.

John HE and Cunningham JR. 2004. The Physics of Radiology Fourth Edition. Charles C Thomas Publisher : Spring-field Illinois 62717 USA.

Cahyono HA. 2003. Inspeksi Keramik dengan Radiografi Sinar-X. Skripsi S-1, FMIPA UGM, Yogyakarta.

Pasolang G. 2003. Inspeksi Pipa Berbasis Radiografi Sinar-X Digital. Skripsi S-1, FMIPA, UGM, Yogyakarta.

Fidiani E. 2008. Studi Awal Inspeksi Kandungan Logam dalam Cat de-ngan Teknik Computed Radiography. Skripsi S-1, FMIPA UGM, Yogyakarta.

Setiawan SA. 2002. Interpretasi Radiograf Digital pada Industri Pengelasan Pipa. Skipsi S-1, FMIPA UGM, Yog-yakarta.

Wahyuningsih M. 2009. Perbandingan Kualitas Citra Computed Radiography dengan Citra Hasil Digitisasi Film Radiograf. Skripsi-S1. FMIPA UGM.

Beiser A. 1987. Concepts of Modern Physics, 4th Edition, McGraw-Hill, Inc., Diterjemahkan oleh The hauw Lion, 1992, Konsep Fisika Modern, Erlangga, Bandung.

Suyatno F. 2008. Aplikasi Radiasi Sinar-X di Bidang Kedokteran Untuk Menunjang Kesehatan Masyarakat, Seminar Na-sional IV SDM Teknologi Nuklir, Yogyakarta.

Trikasjono T, Marjanto D dan Nugroho A. 2007. Perancangan Ruang Pengujian Kebocoran Pesawat Sinar X Rigaku 250 KV di STTN Batan Yogyakarta, Seminar Nasional III SDM Teknologi Nuklir, Yogyakarta.

Muhtadan. 2008. Pengembangan aplikasi untuk perbaikan Citra digital film radiografi. Dalam http://www.jur-nal.sttn-batan.ac.id/wp-content/up-loads/2008/12/49_muhtadan467-478.pdf- , (Diakses tanggal 1 Mei 2009)

Muhtadan 2009. Subscriber_Identity_Module. Dalamhttp://en.wikipedia.org/wiki/Subs-criber_Identity_Module.htm, (Diakses tanggal 2 Mei 2009).




DOI: http://dx.doi.org/10.31958/js.v4i1.57

Refbacks

  • There are currently no refbacks.


Copyright (c) 2016 SRI MAIYENA

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Indexed by:

        

 

__________________________________________________________________________

Sainstek: Jurnal Sains dan Teknologi
ISSN 2085-8019  (print) | 2580-278x  (online)
Published by Institut Agama Islam Negeri Batusangkar

Email: sainstek@iainbatusangkar.ac.id


View Sainstek Stats

 

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.