PENGUKURAN DOSIS EFEKTIF ORGAN TYROID DAN MATA PADA PEMERIKSAAN MAMMOGRAFI

Lody Firmansyah

Abstract


A research has been done about the effective dose measurement of thyroid and eye organ on mammography examination. The aims of the research is to determine the radiation dose absorbed by the thyroid organ and eye examination Mammography. This research uses TLD-100 as a radiation measuring instrument. The data retrieval process has taken place in Parahita Laboratorium, Jakarta by collecting five of patients data to have Mammography radiology examination, the research is done by putting the TLD-100 in every side of thyroid organ and eye to know the value radiation dose which occurs in Mammography examination. Eksposi factors used in this study was 29 kV and 250 mA. The result of this research is obtained the value of the dose absorbed by the thyroid organ and less than the limit value of existing dose of 0,7 mSv, To analysts equivalent dose in patients who received organ Mammography is quite safe because less than the value standard dose limits specified.

Key words : mammography, radiation dose, TLD

References


Yudistiro R. 2012. Evaluasi Fungsi Kelenjar Tiroid. Jakarta.

Sudibjo P. 1996. Anatomi Mata. Samarinda: Gunung Kelud.

Tjokronegoro A. 1982. Imunologi Diagnostik dan Terapi. Depok Jawa Barat : Fakultas Kedokteran Universitas Indonesia.

Pravasani A. 2012. Pengaruh Radioterapi Area Kepala dan Leher Terhadap pH Saliva. Skripsi. Semarang: Fakultas Kedokteran Universitas Diponegoro.

Dewiana. 2012. Analisa Dosis Serap Organ Kritis lensa mata pada terapi karsinoma nasofaring dengan pesawat sinar-X 6mV. Skripsi. Jakarta: Fakultas Teknik dan Sains Universitas Nasional.

Anam C. 2013. Analisis Penerimaan Dosis Radiasi Di Organ Mata Pada Pemeriksaan Nasofaring Menggunakan Ct Scan. Skripsi. Semarang: Fakultas Sains dan Matematika Universitas Diponegoro.

Rudi, et al. 2012. Pengukuran Paparan Radiasi Pesawat Sinar x Di Instalasi Radiodiagnostik Untuk Proteksi Radiasi. Unnes Physics Journal. Unnes Physics 1 (1) (2012). Semarang: Jurusan Fisika FMIPA Universitas Negeri Semarang Gunungpati.

Bushong S. 1988. Radiologic Science For Technologists, fourt edition. Washington : C.V. Mosby company.

PERKA BAPETEN NO 8 2011 Tentang Keselamatan Radiasi dalam penggunaan pesawat Sinar-X Radiologi Diagnostik dan Intervensional.

Akhadi M. 2000. Dasar – Dasar Proteksi Radiasi. Jakarta: Rineka Cipta. 41

Edwards C, Statkiewicz M dan Ritenour E. 1990. Perlindungan Radiasi Bagi Pasien dan Dokter Gigi. Jakarta: Widya Medika.

Krane K. 1992. Fisika Modern. Terjemahan oleh Wospakrik. H.J. Jakarta: Universitas Indonesia.

Beiser A. 1992. Konsep Fisika Modern. Jakarta: Erlangga.

Cember H. 1983. Pengantar Fisika Kesehatan. Edisi. Semarang: IKIP Semarang Press.

Suyati dan Akhadi M. 1998. Mengukur Kualitas Radiasi Keluaran Pesawat SinarX. Buletin Alara. 2(2): 7-12.

Kaplan I. 1979. Nuclear Physics, 2 nd edition. London: Addison-Wesley Publishing Company.

Dhahryan AM. 2009. Pengaruh Teknik Tegangan Tinggi terhadap Entrasce Skin Exposure (ESE) dan Laju Paparan Radiasi Hambur pada Pemeriksaan Abdomen. Berkala Fisika. 12 (1): 21-26.

Compagnone G, Pagan L dan Bergamini C. 2005. Comparison of Six Phantoms for Entrance Skin Dose Evaluation in 11 Standard X-Ray Examinations. Journal of Applied Clinical Medical Physics. 6(1):101-113.

Sharifat, Oyeleke OI. 2009. Patient Entrance Skin Doses at Minna and Ibadan for Common Diagnostic Radiological Examinations. Bayero Journal of Pure and Applied Sciences. 2(1): 1-5.

Waseso. 1998. Pengaruh Variasi Tegangan dan Arus Terhadap Kualitas Radiograf dan Dosis Yang Diterima Pasien pada Pemotretan Paru-Paru Proyeksi Postero Anterior (Study Kasus Di RSPAD “Gatot Soebroto“Jakarta). Skripsi. Semarang :Universitas Dipenegoro. 42.

Fahmi A, Firdausi KS, Budi WS. 2008. Pengaruh Faktor Eksposi pada Pemeriksaan Abdomen terhadap Kualitas Radiograf dan Paparan Radiasi menggunakan Computed Radiography. Berkala Fisika. 11 (4): 109- 118.

Sofyan H, Akhadi M, Prasetio H, Budiantari CT, Nuraeni N. 2012. Uji Karakteristik Dosimeter TL LiF:MG,Cu,P dan Dpsimeter OSL dan Pengembangan Metode Audit Dosimeter Fasilitas Radiologi untuk Peningtkatan Layanan dan Keselamatan Pasien Anak. Jakarta: Batan.

Pearce EC. 2009. Anatomi dan fisiologi untuk Paramedis. Jakarta: PT Gramedia Pustaka Utama.




DOI: http://dx.doi.org/10.31958/js.v8i1.437

Refbacks

  • There are currently no refbacks.


Copyright (c) 2017 Lody Firmansyah

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Indexed by:

        

 

__________________________________________________________________________

Sainstek: Jurnal Sains dan Teknologi
ISSN 2085-8019  (print) | 2580-278x  (online)
Published by Institut Agama Islam Negeri Batusangkar

Email: sainstek@iainbatusangkar.ac.id


View Sainstek Stats

 

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.