Abstract


Electromagnetic radiation on television has been analyzed. The aim is to create a radiation distribution pattern and compare the electromagnetic radiation of Tube television and LED television. In this study, radiation measurements using an electromagnetic radiation sensor. Radiation exposure dose measurements were carried out at 25 measurement points in the television room, namely 5 points each on the track and 1 point in the center of the radiation source. The data processing method uses Scilab to create radiation distribution patterns. The results of data processing showed that the largest radiation exposure dose was on line C (in front of television) for 60 minutes. The radiation value of Tube television is greater than the radiation value of LED television. The isodose contour shows the radiation exposure dose value of 0 at a distance of 2.5 m from the TV, which is the safe limit for watching.

Keywords


Electromagnetic radiation; Tube television; LED television; Isodose contour; Scilab.

Full Text:

PDF

References


Agung Yanuar Wirapraja, Ika Prawesty Wulandari and Mohamad marhaendra Ali, (2020). The effect of TV pattern test. on 30 MHz - 1 GHz Radiated Emission Characteristic of LED Television. Journal of Technology Process. 5(2).

Andy Nugroho Piro Utomo, (2021). The eye safety distance controller television monitor screen is based on microcontroller. Thesis of Muhammadiyah University Ponorogo.

Johan Aristo, Purnomosutji Dyah prinajati, and Nafsan Upara (2020). Analysis of the amount of TV electromagnetic radiation in the work environment. SEOI Journal. 2(1).

Kemal Dervić, Vladimir Šinik, Željko Despotović. (2019). Basic of electromagnetic radiation. IX International Conference Industrial Engineering and Environmental Protection. Zrenjanin, Serbia

Muhammad Niki Bagus Wahyune Sukma. (2022). Detection of electromagnetic wave radiation from television equipment in Sumbertebu village. Experiment : Journal of Science Education. 2(1) : 29-34.

Nanda, K., Kazi, M., Farhana, I., Marjanul, H., Razzak, Mollah, M., and Ruhul, A. (2021). Fundamental characteristics and application of radiation. GSC Advanced Research and Review. 07(01): 064–072.

Peter Johnston. (2020). Making sense of radiation safety. Department of Nuclear Safety and Security.

Tulfala F, and Kasman. (2020). Analysis of Contour Isodosis of X-Ray Radiation Exposure at the Radiology Installation at the Madani Palu General Hospital. Gravitasi Journal 19-1: 20-23.

Yamin Sun, Zhiyong Yu, Chen Pang. (2019). Study on radiation characteristics of electromagnetic equipment. IOP Conf. Series, Journal of Physics: 1237-042073.




DOI: http://dx.doi.org/10.31958/js.v15i2.10511

Refbacks

  • There are currently no refbacks.


Copyright (c) 2023 Reskiyati, Anis Nismayanti, Sitti Rugayya, Kasman, Hosiana MD Labania, Badaruddin, Agung Danu Wijaya

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Indexed by:

        

 

__________________________________________________________________________

Sainstek: Jurnal Sains dan Teknologi
ISSN 2085-8019  (print) | 2580-278x  (online)
Published by Institut Agama Islam Negeri Batusangkar

Email: sainstek@iainbatusangkar.ac.id


View Sainstek Stats

 

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.